The Performance of External Vertical Slats for Shading West Windows in Office Buildings

Authors

  • Evance Melkiory Haule The Joint Graduate School of Energy and Environment, CHE Center for Energy Technology and Environment, King Mongkut’s University of Technology Thonburi, Bangkok 10140 Thailand.
  • Pipat Chaiwiwatworakul The Joint Graduate School of Energy and Environment, CHE Center for Energy Technology and Environment, King Mongkut’s University of Technology Thonburi, Bangkok 10140 Thailand.
  • Surapong Chirarattananon The Joint Graduate School of Energy and Environment, CHE Center for Energy Technology and Environment, King Mongkut’s University of Technology Thonburi, Bangkok 10140 Thailand.

DOI:

https://doi.org/10.14456/nujst.2020.27

Keywords:

Solar radiation, Shading devices, External vertical slats, Heat reflective glass and Energy saving

Abstract

        In a hot climate region, the solar radiation transmitted into the building is very high throughout the year. This causes the consumption of electricity to be higher in terms of air-conditioning. The usages of shading devices are necessary to overcome the problem of glare and solar radiation. The uses of external vertical shading devices in west windows are more effective than horizontal shading devices because the sun is travelling overhead all the time.

        In most office buildings, the heat reflective glasses (HR) are used to reduce the solar radiation. Therefore, this paper discusses the performance of external vertical slats with clear glass and compares the results obtained from the heat reflective glass window in west exposure. The daylighting performance was evaluated for both cases of using external vertical slats and HR in June and December to check variations. The results of the simulation showed that the application of external vertical slats always reduces energy consumption for three window to window ratio (0.3WWR, 0.6WWR and 0.9WWR) scenarios this is beneficial to the occupants. The results indicate that using the external vertical slats in the west façade achieving potential energy savings ranging between 16%– 52% less energy compared to heat reflective glass.

References

Arifin, N. A. (2015). An analysis of indoor air temperature and relative humidity in office room with various external shading devices in Malaysia. Procedia-Social and behavioral Sciences, 176, 290-296.

Australia Building. (2012). Council of Australian Governments. Baseline Energy Consumption and Greenhouse Gas Emissions in Commercial Buildings in Australia: Council of Australian Governments.

Carmody, J., Selkowitz, S., Arasteh, D., & Heschong, L. (2000). Residential Windows: A Guide to New Technologies and Energy Performance. New York: W.W Norton & Company.

Ching, F. D., & Shapiro, I. M. (2014). Green Building Illustrated. Hoboken, N.J.: Wiley.

Chirarattananon, S. (2005). Building for Energy Efficiency. Bangkok, Thailand: Asian Institute of Technology.

Husin, S. N. F., & Harith, Z.Y.H. (2012). The Performance of Daylight through Various Type of Fenestration in Residential Building. Procedia - Social and Behavioral Sciences, 36, 196 – 203.

IEA. (2012). International Energy Agency, Energy Policies of IEA Countries. Retrieved from http://www.

iea.org/publications/freepublications/publication/Korea2012_free.pdf.

IESNA. (1993). American National Standard Practice for Office Lighting. Illuminating Engineering Society of North America: America.

Kandilli, C., & Ulgen, K. (2008). Solar Illumination and Estimating Daylight Availability of Global Solar Irradiance. Energy Sources, 30, 1127-1140.

Lencher, N. (2009). Heating, Cooling, Lighting: Sustainable Design Methods for Architect. Hoboken, NJ: John Wiley & Sons.

Nabil, A., & Mardaljevic, J. (2006). Useful daylight illuminances: A replacement for daylight factors, Energy and Buildings, 38, 905-913.

Rosa, L. P., & Lomardo, L. L. B. (2004). The Brazilian energy crisis and a study to support building efficiency legislation. Energy and Building, 36, 89-95.

Zain, A. A., Sopian, K., Othman, M. Y. H., & Abidin, Z. Z. (2002). The Availability of Daylight from Tropical Skies: A Case Study of Malaysia, Renewable Energy, 25, 21-30.

Downloads

Published

2020-06-05

Issue

Section

Research Articles